1. Pumping rate (volume flow rate) (s unit: m3·min-1, m3·s-1, L·s-1) When the pump is equipped with a standard test hood and operates under specified conditions, the ratio of the gas flow through the test hood to the equilibrium pressure measured at the specified position on the test hood. Referred to as the pumping speed of the pump. That is, under a certain pressure and temperature, the volume of gas pumped by the vacuum pump from the pumped container per unit time. 2. Ultimate pressure (ultimate vacuum) (unit: Pa/MPa/mmHg) The pump is equipped with a standard test cover and works according to the specified conditions, and tends to a stable minimum pressure without introducing gas to work normally. That is, the lowest stable pressure that can be achieved at the inlet end of the vacuum pump after being fully pumped. 3. starting pressure The pressure at which the pump starts without damage and has a suction effect 4. Foreline pressure The outlet pressure of a vacuum pump where the exhaust pressure is less than one atmosphere pressure. 5. Maximum foreline pressure The foreline pressure that can damage the pump has been exceeded.

Detailed information


1. Pumping rate (volume flow rate) (s unit: m3·min-1, m3·s-1, L·s-1)

When the pump is equipped with a standard test hood and operates under specified conditions, the ratio of the gas flow through the test hood to the equilibrium pressure measured at the specified position on the test hood. Referred to as the pumping speed of the pump. That is, under a certain pressure and temperature, the volume of gas pumped by the vacuum pump from the pumped container per unit time.

2. Ultimate pressure (ultimate vacuum) (unit: Pa/MPa/mmHg)

The pump is equipped with a standard test cover and works according to the specified conditions, and tends to a stable minimum pressure without introducing gas to work normally. That is, the lowest stable pressure that can be achieved at the inlet end of the vacuum pump after being fully pumped.

3. starting pressure

The pressure at which the pump starts without damage and has a suction effect

4. Foreline pressure

The outlet pressure of a vacuum pump where the exhaust pressure is less than one atmosphere pressure.

5. Maximum foreline pressure

The foreline pressure that can damage the pump has been exceeded.